| Subject: | Re: question before I remove the fridge |
| From: | Germain |
| Date: | Wed, 18 May 2005 18:05:12 -0400 |
Hi Harold Removing the fridge and cleaning the combustion chamber will help a lot. You might have some dust accumulated inside the combustion chamber which could prevent the spark to lite properly the small jet of propane or the quality of the flame is bad. When the combustion chamber is cleaned, it is very easy to light the fridge. Good luck ----- Original Message ----- From: "Harold Teer" <teer.vanagon@GMAIL.COM> To: <vanagon@GERRY.VANAGON.COM> Sent: Wednesday, May 18, 2005 12:48 PM Subject: question before I remove the fridge For the 9 years I have owned my van, I have been able to light the fridge with minimal difficulty. I am now having a problem and need some advice. Before, when lighting the fridge, I would follow the directions and when I pushed the button for gas mode, the light would flicker, I would hold down the "flame failure safety device" and pump like crazy until the light quit flashing and I would have an operating fridge. Now, when I push the button for gas mode, the light comes on but does not flicker. Thus, it acts as if the fridge is lite when in fact it is not. Any idea what might be wrong or what is happening. The fridge works on AC, I had it on all day yesterday and it cooled fine. I have propane because both the stove and the Propex heater work. Thanks for any advice. Harold -- Harold Teer Harrisonburg, VA 1991 Westy
Have something to add on this topic today? Revive this thread in the forum »