| Subject: | SV: Expansion tank not connected |
| From: | Jens Jakob Andersen |
| Date: | Thu, 30 Dec 2004 22:04:24 +0100 |
Hi I have the expansionb tank. Yup. I have the overflow tank. I am missing pipe between those two. ANy valves or similar there, or just a piece of pipe? /JJ -----Oprindelig meddelelse----- Fra: John Rodgers [mailto:inua@charter.net] Sendt: 30. december 2004 14:29 Til: Jens Jakob Andersen, PDI Cc: vanagon@GERRY.VANAGON.COM Emne: Re: Expansion tank not connected You should have two tanks in the system. As seen from the rear of the van looking forward, the expansion tank should be on the left, just forward of the bumper. The overflow tank should be in the middle just in front of the bumper and with the fill cap exposed to the access door where the vehicle tag mounts. There should be a small hose from the expansion tank cap over to the bottom right side of the overflow tank. There should be two hoses or connections to the expansion tank. And there should be a sensor in the top of the expansion tank. If you don't have all these things..........then Yup!, your cooling system is incomplete. Regards, John Rodgers 88 GL Driver Jens Jakob Andersen wrote: >Howdy > >On my WBX, the expansion tank is NOT connected. > >A bit weird... > >I am not sure why this, and what is missing. > >Any experts out there on the cooling system? > >/JJ > > > >
Have something to add on this topic today? Revive this thread in the forum »