Skip to main content
vanagon.com
Checking account...
← vanagon.com home · Continue the discussion in the forum
VanagonEuroVan
Subject:Re: O2 Sensors need grounding? (was STILL BUCKING & KICKING!!!)
From:David Beierl
Date:Mon, 14 Aug 2000 10:55:20 +0000

At 12:38 8/13/2000, Gary Stearns wrote:
>Do oxygen sensors require grounding through the exhaust system?

Yes

>  Could this
>be why exhaust work would mysteriously cure b&k?

Yes, ie yes could be, not yes is.

>   Could the anti-seize goop
>I put on the threads (only on the threads, not on the sensor)  be isolating
>my sensor?  Just curious.

It's quite possible that the antiseize poisoned your sensor and ruined
it.  I did it to one of Jon Casey's a month ago by being thoughtless -- the
sensors come with a dab of "safe" antiseize already applied to the
threads.  This was a reinstall and I don't know what/where to get stuff
that's safe -- it may even be that they simply are very careful where it's
applied, though I doubt it.  Anyway, Jon's lasted about five or maybe ten
minutes before it was toast.

I doubt that it would interfere with the connection though, if the sensor
were tightened reasonably.

david
David Beierl - Providence, RI
  http://pws.prserv.net/synergy/Vanagon/
'84 Westy "Dutiful Passage"
'85 GL "Poor Relation"

Have something to add on this topic today? Revive this thread in the forum »