| Subject: | Re: bad ground on radiator fan motor |
| From: | Thomas Casal |
| Date: | Sun, 29 Aug 2021 16:39:15 -0400 |
Hey Guys, I'm Reviving an old thread here. I have an older style fan and was curious what the best way to add an extra ground is. Can I just attach the wire to the body of the fan with a carefully placed screw? If not what would be the best way to add an extra ground wire. My fan hasn't worked in a minute I confirmed that the motor was good by jumpering it. Fan was intermittent for a while then totally died. On Thu, Jan 4, 2018 at 5:34 PM vw_van_fan_Mark <madvws@cox.net> wrote: > Yes, the failed rad fan ground connection has become pretty common > lately and often becomes intermittent first. I often add a dedicated > local ground wire but I drill a hole in the chassis nearby so anyone > working on the rad fan/wiring in the future can plainly see the added > ground point. > > You can find the big fan and resistor in the wiring diagrams for the A/C > system since it is only 86+ vans with factory A/C that got it. (All > Syncros got it but unless they had A/C they used a simpler wiring > diagram on page 97.200) > > Mark > > gary hradek wrote: > > There is a lot of information on the vanagon fan motorsystem. Ken at > Vanagain and Go Westyhave some good postings to trouble shoot as well as > the archives. I would like to try to fill in some of theblank space in > the trouble shooting area. > > > > I have 87 westywith AC that is very much like the 86 westy, the fan > motor system on the olderand newer vanagon are only slightly different. I > am not sure why but the Bentley manual does not show the resistor inthe > electronic diagram. > > > > My low speed fanwas not going on. Following Ken atVanagain > protocol I jumpered the sensor and nothing happened. Ken does not > indicate what to do in thissituation. I should add that the fandid not > come on when I turned on the AC. Baffled, I wasted a lot of time looking > at the wrong things. A situation like this you should look againat the 30 > amp fuse and check that fuse time to time as you trouble shoot. At this > point you should drop the spare tireand use an external power source to > confirm that the motor itself is notbad. It is unlikely to be bad. > When I looked at the motor what I saw werethree wires. The medium size > groundbrown wire, the medium size red low speed wire and the massive red > high speedwire. What were the Germans smokingwhen they made the ground > wire smaller than the power wire? To confirm the ground wire problem I > pulledthe resistor connector behind the headlight and applied 12 volts to > the mediumred wire that goes to the fan motor with Ken’s jumper protocol > and confirmed that the fan motor did not comeon. I then jumpered the > brown groundterminal to various locations near the fan motor with (Ken’s > protocol jumpersetup) and the red wire from the resistor energized and > found a good ground andthe fan came on. My final location fora new 12 > gauge ground wire was the horn bracket attachment to the frame. The newer > style fan motors have a screwattachment for the wires. Not sure whatis > the best way to add the ground wire for the older style clip arrangement. > > > > Looking back at thelast summer I can recall that I must have had an > intermittent ground problembefore the acute failure. There weretimes when > the temperature gauge read higher than it usual. I would suggest any one > who has not added asecond ground wire consider doing this the next time > they go to check theirspare. It is not something you want tomess with on > the road on the hottest day of the year. > > > > > > >
Have something to add on this topic today? Revive this thread in the forum »