Subject:Fixed (Re: dometic pilot goes out when thermostat turned up)
From:Andy Highland
Date:Mon, 10 Jul 2006 21:19:01 -0700

On Jun 23, 2006, at 12:05 AM, Andy Highland wrote:

> My dometic lights and stays lit as long at the thermostat is left at
> 0. When I turn it up, the pilot goes out. : ( Has anyone had this
> problem?
>
> Thanks,
> andy

Thanks for all the suggestions. I pulled the fridge and checked the
combustion chamber. There was a little bit of gunk and rust in there,
but not very much. I cleaned it out. I also blew as hard as I could
through both flue vents. I put it back in the cabinet and It ran for
almost a day on propane with the thermostat at MAX before I shut it
off. So, the problem was either in the flue vent system or the
combustion chamber. My guess is that one of the flue pipes was
blocked which allowed enough fresh air for the pilot, but not for a
bigger flame and so it went out when the thermostat knob was turned up.

While I had it out I took the insulation sleeve off of the flue
pipes. I couldn't remember if it was supposed to wrap around both
pipes or just the exhaust. I couldn't get it to wrap around both, so
it's now just on the exhaust pipe. I hope I got that right.

yay!