Hi all,
I am going to check & maybe adjust my CO today & wanted to make sure I
understood how to do this. Warmed up, hook the + lead of the VOM to the
single black wire from the O2 sensor, ground the - VOM lead. The reading
should be .5V. Higher is richer & visa-versa. Anything else to consider?
Thanks.
Pat Callaghan
87 Westy GL
Portland, OR.