| Subject: | Re: propane question |
| From: | David Beierl |
| Date: | Sat, 29 Apr 2000 02:24:51 -0400 |
At 13:59 4/28/2000, Davidson wrote: >Bob, >I imagine you could splice a T into the copper propane lines that would >allow you to hook up a portable propane tank.... but why would you want to >do this? and.... remember the portables are not supposed to be used indoors >near an open flame.... that's because they have pressure relief valves that >could open... spewing propane out into the air! Nuh-huh. That would put 100 psi or so into a system designed for about 1/3 psi. You have to either supply a two-stage regulator with output at 11" WC (water column, about 6 ounces per square inch), or tap in upstream of the existing regulator. There is a product called Extend-a-Stay which will parallel the built-in tank with a BBQ tank, so you can draw vapor off the BBQ tank while you're staying put. I don't know whether it shuts off the main tank at the same time -- if not the main flow would come from whichever tank was warmer. Just incidentally, a 16-oz (the wide stubby kind) propane tank would run one burner about 4 hours. david David Beierl - Providence, RI http://pws.prserv.net/synergy/Vanagon/ '84 Westy "Dutiful Passage" '85 GL "Poor Relation"
Have something to add on this topic today? Revive this thread in the forum »