Subject:Re: AC Electrical
From:John Rodgers <jrodgers113@GMAIL.COM>
Date:Fri, 4 Aug 2023 16:54:45 -0500

Not sure what  an inline MAX fuse holder is.  50 Amp fuse I got.

On Fri, Aug 4, 2023 at 4:27 PM Dennis Haynes <d23haynes57@hotmail.com>
wrote:

> This set up melting is a common problem. Best fix is to replace with a
> standardized fuse holder and set up. Easy fix is to splice in an inline MAX
> fuse holder with 50 Amp fuse. Most likely the failure began at the wire
> terminal crimp connections.
>
> Dennis
>
>
> -----Original Message-----
> From: Vanagon Mailing List <vanagon@gerry.vanagon.com> On Behalf Of John
> Rodgers
> Sent: Friday, August 4, 2023 3:39 PM
> To: vanagon@GERRY.VANAGON.COM
> Subject: AC Electrical
>
> In the D pillar the 50 amp AC Fuse blew. Went to install a new one only to
> discover the original overheated before it blew and melted the
> rubber/plastic that holds the brass screw holder which in turn holds the
> fuse in place. It is PART# 251937501B and is NLA.- It's been discontinued.
> Would anyone have one of these or know where I might find one?
>
> Royal 0Volkswagon  here in Birmingham, a dealership, was a huge help in
> tracking down this part number and finding a parts blow-up of this and
> sending me a copy.
>