| Subject: | Re: Leaking heater control valve |
| From: | Richard Koerner <rjkinpb@SBCGLOBAL.NET> |
| Date: | Thu, 16 Sep 2021 01:49:52 +0000 |
I guess there are 2 kinds of leaks on that front heater control valve. The first one is where the valve doesn't quite shut off all the way and you get Vanagon "hot foot". The second one is where valve actually leaks coolant to the outside; your situation sounds very minor. But replacement when convenient seems like a wise move so put it on the list and order replacement valve now so you have ready to go.
On Wednesday, September 15, 2021, 06:19:11 PM PDT, Jim. Felder <jim.felder@gmail.com> wrote:
You will not get heat in the front, that’s the only downside… as long as
your ailing valve holds as it is. If you will be traveling g it might be
wise to buy a cheap set of hose clamps and put one on either side of the
valve. This can be done in the cabin by dropping the glove box and center
heater panel.
Jim
On Wed, Sep 15, 2021 at 8:12 PM Bruce Todd <beeceetee@gmail.com> wrote:
> I am heading out Friday on a short trip to head out into the back
> country with a few other van owners and I noticed a small stain under the
> front clam shell this afternoon.
>
> It looks like it is dripping from the heater control valve. I shut the
> valve and that has stopped the drips for now. I have yet to run the van to
> see if that continues to keep things at bay.
>
> So my question is - but shutting the valve will that hopefully me from
> losing coolant for the short term until it is replaced? And will there be
> any ramifications for turning off the valve - other than I will likely
> not be getting much heat in the front of the cab?
>
> Bruce
>